Board Description; Connection Of The Power Supply Line; Type Of Cable - Avigilon ES-HD-HWS Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28

6.1.3 Board description

Connect the safety earth to the relative
terminal of the J1 connector.
The board may appear different to that
illustrated.
Depending on the product version, the
board may not be equipped with all
functions.
BOARD DESCRIPTION
Connector
Function
J1
Board power supply (V
J2
Auxiliary output (V
J3
Heater power supply (V
J4
Tamper switch contacts3
J5
Camera power supply (V
J7
Connector for power supply/jumper
J8
Fan power supply (V
SW1
Tamper switch3
Tab. 1
From 24V AC or 12V DC.
1
Same voltage applied to J1.
2
Optional.
3
Different alternatives are available depending
4
on the version. V
relation to the type of power supply installed . V
V
, only for housings powered in 12V DC or 24V AC,
IN
with jumper inserted in J7.
J8
SW1
J7
Fig. 4
ES-HD-HWS/ES-HD-CWS/ES-HD-HWS-LG/ES-HD-CWS-LG
)1
IN
)2
OUT
)
OUT
)4
OUT
)
OUT
= 12V DC or V
= 24V AC, in
OUT
OUT
J2
J1
J4
J3
J5
6.1.4 Connection of the power supply
line
Insert the cables for the connection to the power
supply line inside the housing through the
cable glands. The cable glands are suitable for
conductors with diameters of between 5mm and
10mm. The section of the cable inside the housing
must be sufficiently long to allow connection.
Suitably lock the cable glands.
Remove the conductors protective sheathing
and connect them to terminal (J1, 6.1.3 Board
description, page 7).
Make sure the earth conductor is at least 10mm
longer than the others.

6.1.4.1 Type of cable

The cable used for the connection to the power
supply line must be suitable for the intended use.
Comply with the current national standards on
electrical installations.
=
OUT