Product Description And Type Designation; Product Markings - Avigilon ES-HD-HWS Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
• The electrical system to which the unit is
connected must be equipped with a automatic
bipolar circuit breaker. The circuit breaker for
main supply voltage phase units must have a
level of intervention of 20A max. The circuit
breaker for low voltage units must have a level
of intervention of 6A max. This circuit breaker
must be of the Listed type. The minimum
distance between the contacts must be 3mm
(0.1in). The circuit breaker must be provided
with protection against the fault current towards
the ground (differential) and the overcurrent
(magnetothermal).
• Any device which could be installed inside the
product must comply with the current safety
standards.
• If the installation is NEMA TYPE 4X, the installer
must replace the cable glands of the product
with NEMA TYPE 4X cable glands.
• Installation category (also called Overvoltage
Category) specifies the level of mains voltage
surges that the equipment will be subjected
to. The category depends upon the location
of the equipment, and on any external surge
protection provided. Equipment in an industrial
environment, directly connected to major
feeders/short branch circuits, is subjected to
Installation Category III. If this is the case, a
reduction to Installation Category II is required.
This can be achieved by use of an insulating
transformer with an earthed screen between
primary and secondary, or by fitting listed
Surge Protective Devices (SPDs) from live
to neutral and from neutral to earth. Listed
SPDs shall be designed for repeated limiting
of transient voltage surges, suitable rated
for operating voltage and designated as
follows: Type 2 (Permanently connected SPDs
intended for installation on the load side of
the service equipment overcurrent device);
Nominal Discharge Current (In) 20kA min. For
example: FERRAZ SHAWMUT, STT2240SPG-
CN, STT2BL240SPG-CN rated 120/240V AC,
(In=20kA). Maximum distance between
installation and reduction is 5m.
4
• For all connections, use cables that are able to
withstand temperatures of at least 75°C (167°F).
• The product is designed to house only cameras
that are properly certified (7W max).
• A disconnecting device, readily and easily
accessible, must be incorporated in the
electrical system of the building for rapid
intervention.
• To connect the power supply line use the
appropriate junction-box (UPTJBUL). For further
information, refer to the product use and
installation manual.
• Use Listed copper tube crimping lugs for the
connection of the network conductors to the
terminals. The copper tube crimping lugs must
be suitable for the type of installation (from
-20°C (-4°F) to +80°C (+176°F) min., V-0). Copper
tube crimping lugs examples: RP, BP or YP
(Cembre).
4 Identification
4.1 Product description and type
designation
Robust aluminium housing designed to simplify
the installation and service and guarantee total
protection against all environmental conditions.
Its size makes it ideal for housing various
combinations of standard cameras with fixed or
compact zoom lenses.
Very easy to install thanks to the side opening
system that allows the full access to the camera,
lenses and all internal connections.
A wide range of accessories for mounting the
equipment is available thereby satisfying all
installation needs.

4.2 Product markings

See the label attached to the product.
ES-HD-HWS/ES-HD-CWS/ES-HD-HWS-LG/ES-HD-CWS-LG

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Es-hd-cwsEs-hd-hws-lgEs-hd-cws-lg

Table des Matières