PRODUCT GUARANTEE:
The product is guaranteed as per Italian Presidential Decree
224 of 24/05/1988 in Italy and the rest of the EU and as
per CEE Directive 85/374 in terms of product liability.
The Manufacturer guarantees its products against
manufacturing and material defects – provided these are
confirmed by the authorised personnel of the Company
– for a period of 24 months from the purchase date, as
indicated by the receipt or invoice.
The guarantee covers repairs to and/or replacement of
the parts considered to be faulty. The guarantee does not
cover complete replacement of the product. The guarantee
does not cover the lights, warning lights, fuses, glass parts,
mirrors and decoration parts unless these are faulty due
to production defects and not due to neglect or improper
use. The guarantee does not cover any parts and
components which are faulty or damaged due to negligence
or carelessness during use, incorrect installation or
maintenance, operations carried out by non-authorised
personnel, damage caused during transport or any other
circumstances not due to product manufacturing defects,
such as sudden electricity jolts, lightning, electrolysis,
corrosion and, in general, any causes related to the nature
of the water and electrical and water supply systems in
the place where the unit is used. The Purchaser must
check that the product is not damaged in any way before
installation and must contact the agent or authorised
assistance centre immediately if any faults are detected.
The guarantee will only be applied on presentation of a
document indicating the purchase date.
In the event of operations without proven defects or to
illustrate how to use the product, all the expenses are
sustained by the Purchaser. Any repairs or modifications
carried out by personnel not authorised by the Manufacturer
will not be covered by the guarantee and will render the
remaining guarantee period immediately null and void.
The Manufacturer is not responsible in any way for any
direct or indirect damage caused to persons, animals or
things due to failure to comply with all the regulations in
the installation, instruction and maintenance manual
supplied with the product.
Any disputes will be dealt with exclusively by Mantova
Italy, Law Court.
This symbol indicates important product instructions
or important safety information.
IMPORTANT:
Before you start to assemble and install the product,
carefully read through all the instructions. Unpack the
components and check that nothing is missing and that
there are no damaged or faulty components, remove the
transparent protective film. Before you install the shower
cubicle in its final position, perform a test run. Run the unit
for several minutes and check for water leaks and any
damage caused during transport and handling. This product
should be installed by suitably skilled personnel.
N.B.: This product is designed for installation on finished
walls and floors.
Warranty claims must be produced with the purchase
invoice and the product assembling instructions.
The drawings and illustrations in this manual are provided
for information purposes only.
The manufacturer reserves the right to make changes and
improvements without prior notice.
Electrical connection:
Novellini S.p.a. hereby certifies that the product conforms
to current health and safety regulations at the time of sale
and that the product has the CE-mark and Declaration of
Conformity. All products and components are tested during
manufacture in accordance with the relevant reference
standards and company quality system procedures. In
order to ensure that your Novellini product maintains these
high standards after installation and throughout its service
life, please read the following instructions.
1. Check that the mains electrical equipment connected
to cubicle conforms to current electrical standards and
regulations and is fitted with a fully efficient earth
connection.
2. Current electrical regulations forbid the installation of
any electrical equipment (e.g. plugs, switches) inside a
radius of 60 cm from the cubicle and at a height of 225
All manuals and user guides at all-guides.com
cm.
3. Check that rating of the mains power supply line matches
the absorbed power specified for the cubicle (see Technical
specifications, page 4).
4. The electrical connection between the cubicle and the
mains must be protected against water spray and must
have a protection rating of IP55 or higher.
5. The electrical equipment upstream from the cubicle
must be fitted with an omnipolare 30 mA switched circuit
breaker with a minimum contact opening of 3 mm, which
conforms to current electrical regulations
6. The steam unit has an earth terminal which must be
connected to the auxiliary earth connecting all the metal
components of the unit (
), (see the drawing on page
12).
7. Novellini S.p.a. declines all responsibility for injury or
damage resulting from failure to observe these instructions.
~
0
STEAM:
Once power is turned on, the display shows:
ADJUST TIME:
Time can be adjusted in stand-by only.
Hold down the
button for a few seconds, the hours
flash. Press
and
to adjust.
Press
to confirm and go on to the minutes. Press
and
to adjust.
Press
to confirm. The time is set.
LOCATING AND MEMORISING THE RADIO:
1) Press
to turn the radio on. Use buttons
to adjust the volume.
2) Press
by moving with the
memorise.
Press
to go from M0 to M9 to change the stations
memorised.
Repeat these steps to locate and memorise other channels.
600 mm
1
2400 mm
2
SETTING THE SAUNA:
3
(I)
The length of the sauna must be set before starting the
sauna cycle (stand-by).
Press
. The length of the sauna shows on the display.
Press
and
minimum of 5 minutes to a maximum of 40. The value
set will be proposed again the next time you use the sauna.
Press
to start the sauna. After about 8 minutes, the
system emits a beep to indicate that the sauna is at
temperature and you can enter the cubicle.
During the sauna you can set the required climate.
When
is pressed, the climate indicators flash.
Use the
and
or maximum climate.
After a few seconds from selection, the climate indicators
stop flashing and the climate selected is set.
After the set time, the system emits a beep to indicate the
sauna is over.
ALARM:
In case of necessity, the alarm button
at any time. When pressed, the heat generator goes off
immediately together with all other functions, activating a
warning signal (after 15 minutes it goes off automatically).
To deactivate it before, just press any other button.
MAINTENANCE AND CLEANING:
After 20 saunas, the symbol
indicating that a cleaning cycle is required.
also perform a cleaning cycle if the sauna is not used for
a long period.
IMPORTANT!
During cleaning, it is absolutely prohibited to
remain inside the cubicle.
Remove the cover from the diffuser and aroma container.
To activate the cleaning cycle, in stand-by, hold the
button down for about 8 seconds until the
appears on the display. During the cleaning cycle, the 2
LEDs flash and a warning signal is emitted throughout the
cycle which may take from between 15 to 20 minutes.
and
ENGLISH
(Mhz flashes) to locate the frequency required
and
buttons. Press
to set the length of the sauna from a
buttons to select a minimum, medium
may be pressed
appears on the display
symbol
to
23