Environmental (continued)
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
20% to 80% (non-condensing) with a
maximum humidity gradation of 10% per hour
5% to 95% (non-condensing) with a maximum
humidity gradation of 10% per hour
0.26 Gms from 5–350 Hz for 5 minutes
in operational orientations
1.54 Gms from 10–250 Hz for 10 minutes in all
orientations
Half sine shock in all operational orientations
of 31 G plus or minus 5% with a pulse duration
of 2.6 ms plus or minus 10%
Half sine shock on all six sides of 71 G plus or
minus 5% with a pulse duration of 2 ms plus or
minus 10%
Square wave shock on all six sides of 27 G
with a velocity change at 235 in/sec or greater
–16 to 3,048 m (–50 to 10,000 ft)
NOTE:
For altitudes above 2950 feet, the
maximum operating temperature is derated
1ºF/550 ft.
–16 to 10,600 m (–50 to 35,000 ft)