Power (continued)
Voltage
Heat dissipation
Maximum inrush current
Batteries
System battery
RAID battery (optional)
Physical
Height
Width
Depth
Weight (maximum configuration)
Weight (empty)
Environmental
Temperature
Operating
Storage
14
Getting Started With Your System
90–264 VAC, autoranging, 47-63 Hz
2446.5 BTU/hr maximum (High Output)
1712.9 BTU/hr maximum (Energy Smart)
Under typical line conditions and over
the entire system ambient operating range, the
inrush current may reach 55 A per power
supply for 10 ms or less
CR 2032 3.0-V lithium coin cell
3.7-V lithium ion battery pack
4.26 cm (1.68 in)
48.24 cm (18.99 in) with rack latches
42.4 cm (16.69 in) without rack latches
77.2 cm (30.39 in) with power supplies
and bezel
73.73 cm (29.02 in) without power supplies
and bezel
17.69 kg (39 lb)
13.25 kg (29.2 lb)
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE:
For altitudes above 2950 feet, the
maximum operating temperature is derated
1°F/550 ft.
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour