Basel
Insert
N-24
Steel chimney
Can be installed with steel chimney.
Weight including insert
Basel
Basel Waxed
Illustration (FIG 1)
*The illustration indicates the approximate centre height
of the hole for the flue. Consider possible inclination of
the flue prior to perforating the chimney. Distortions in
floors and walls may influence the height. Dry stack the
fireplace for accurate height and positioning of the
flue/chimney connection.
If a fresh air supply set (accessory) is connected
through the floor, mark where the hole should be.
FIG A indicates recommended floor area.
Safety Distances (FIG 2)
Ensure that the safety distances are complied with.
Please note that these safety distances can vary from
country to country.
The distance from the glass in the door to a lateral wall,
must be of at least 600 mm.
The distance between the top of the convection air
outlet and roof of inflammable material must be at least
380 mm.
The distance from the back of the surround to
flammable wall must be at least 150 mm.
The distance to any inflammable material in front of the
opening of the insert must be of at least 1 m.
Assembly instructions (FIG 3 - FIG 17)
FIG 3: If the fireplace is connected to a chimney at the
top, the smoke lid must be moved to the rear flue outlet.
FIG 5: The bottom elements are glued together and
fastened with clips. Ensure that the sorround is levelled.
398
kg
If needed, adjust with wedges or powder glue.
527
kg
FIG 7: In case fresh air supply ducting is used, pull the
pipe for fresh air through the appropriate hole in the
elements. The hole through the floor must be made
before the fireplace is assembled. See also separate
instructions for fresh air supply ducting (accessory).
FIG 10 / FIG 11 / FIG 14: Ensure that there is a gap
between the insert and the surround as the insert
expand with heat. Read the text on Adjustment for more
information.
FIG 13A: When the rear flue outlet is used, carefully
knock out the perforated area.
FIG 17: Once the fireplace is assembled, fill the joints
with acrylic and even them out with a sponge or
finger and some soapy water, in order to have a clear
indentation between the elements (FIG Z).
GB