Motor Specifications
and Electrical
Requirements
(Cont.)
In the event of a malfunction or
breakdown, grounding provides a path
of least resistance for electrical current
to reduce the risk of electric shock. This
compressor is equipped with an electric
cord having an equipment-grounding
conductor and a grounding plug, as
shown. The plug must be plugged
into a matching outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
Do not modify the plug provided.
If it will not fit the outlet, have the
proper outlet installed by a qualified
electrician.
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. The conductor with
insulation having an outer surface that
is green with or without yellow stripes
is the equipment-grounding conductor.
If repair or replacement of the electric
cord or plug is necessary, do not connect
the equipment-grounding conductor to
a live terminal.
If the grounding instructions are
not completely understood, or if
you are in doubt as to whether the
compressor is properly grounded check
with a qualified electrician or service
personnel.
If not properly
grounded, this
tool can cause an electrical shock,
particularly when used in damp
locations, in proximity of plumbing,
or out of doors.
Grounding
RESET
TEST
Pin
Figure 2 - Grounding Method
Do not use a
grounding adapter
with this product!
All wiring and
electrical
connections should be performed
by a qualified electrician.
Installation must be in accordance
with local codes and national
electrical codes.
of the grounding plug is able to
result in a risk of electric shock. When
repair or replacement of the cord or
plug is required, do not connect the
grounding wire to either flat blade
terminal. The wire with insulation
having an outer surface that is green
with or without yellow stripes is the
grounding wire.
yellow) wire to a live terminal.
and fire damage will result from
inadequate wiring, etc.
EXTENSION CORDS
1. The air compressor should be located
where it can be directly plugged into
an outlet. An extension cord should
not be used with this unit.
2. To avoid loss of power and
overheating, additional air hose
must be used to reach work area
instead of extension cords.
THERMAL OVERLOAD PROTECTOR
automatic reset thermal overload
protector which will shut off motor if
it becomes overheated.
If thermal overload protector shuts
motor OFF frequently look for the
following causes:
1. Low voltage.
2. Wrong gauge wire.
3. Clogged air filter.
4. Lack of proper ventilation.
5. Unit is being used with an extension
cord.
Grounded
See Troubleshooting Chart for corrective
Outlet
action.
down before start-up is possible.
The motor will automatically restart
without warning if left plugged into
electrical outlet, and the motor is
turned on.
Installation
1. Check and tighten all bolts, fittings,
etc., before operating compressor.
2. Operate compressor in a ventilated
area so that compressor may be
properly cooled.
Improper
3. Compressor should be located where
installation
4. To avoid loss of power and
Operation
Never connect
green (or green and
BEFORE FIRST START-UP
BREAK-IN PROCEDURE
Overheating,
Complete this procedure before using
short circuiting
compressor for the first time. Once
completed, it is not necessary to repeat.
1. Turn ON / OFF switch (
2. Open the tank drain valve.
3. Plug in power cord.
4. Turn ON / OFF switch (
5. Turn ON / OFF switch (
6. Unplug power cord.
7. Close drain valve.
The compressor is now ready for use.
This compressor is
BEFORE EACH START-UP
equipped with an
OPERATING PROCEDURE
1. Turn regulator knob fully counter
2. Connect air hose to outlet of
3. Turn ON / OFF Switch (
4. Plug in power cord.
5. Turn ON / OFF Switch (
6. Attach tire chuck or tool to end of
7. Adjust regulator to proper pressure
The motor must
be allowed to cool
As air is depleted from the tank by
use of a tire chuck, tool, etc., the
compressor will restart automatically
at its preset "cut-in" pressure. When
a tool is being used continuously,
the compressor will cycle on and off
automatically.
8. Turn switch to OFF position (
5
CT436100
it can be directly plugged into an
outlet. Do not use extension cords
with this unit.
overheating, it is better to use
additional air hose instead of
extension cords to reach work area.
) to OFF
position (
).
) to ON
position ( ) and run compressor for
30 minutes.
) to OFF
position (
).
clockwise (to the left) to close air
flow.
regulator.
) to OFF
position (
).
) to ON
position ( ) and let compressor run
until it reaches automatic shutoff
pressure.
hose.
for tool or tire. Operate tool per
instructions.
unplug power cord and drain
tank of air when finished using
compressor.