User's Guide
Use the
For example when the display shows " FO d iu ", then press the
key to begin.
The display will show " A2 0.5d ", press the
When you select a suitable value, press the
After pressing the
set it as needed.
When all digits have been set press the
parameter just set, Advance to another parameter if needed or press the
weighing.
FUNCTION
FO d iu
F 1 A20
F2 CAP
F3 bk
F4 inP
F5 Unt
F6 oFF
F7 Prt
F8 CAL
F9 bd
F10 Gru
F11 LAG
24
key to leave a parameter unchanged.
key to set a value, use the
DESCRIPTION
Set the division
Low y HiGH
Detail information as below:
Capacity
d (low division)
1000 kg
2 kg
2000 kg
5 kg
3000 kg
10 kg
5000 kg
10 kg
7500 kg
20 kg
10000 kg
20 kg
15000 kg
50 kg
Zero track
AZ 0.5d,
AZ 1d
AZ
2d,
AZ 4d
Capacity select
1000 kg
2000 kg
3000 kg
5000 kg
7500 kg
10000 kg
15000 kg
Set backlight
bK AU
bK on
bK oFF
Show internal count
Select
kg
on (turn on unit kg)
lb
on (turn on unit lb)
tj
on (turn on unit tj)
hj
on (turn on unit hj)
Auto turn off time
oFF
0 min
turn on all the times
oFF
5 min
turn off auto after 5 minutes
oFF 10 min
turn off auto after 10 minutes
oFF 15 min
turn off auto after 15 minutes
oFF 30 min
turn off auto after 30 minutes
Select print out format
Cont:
continue send (mostly use in computer communition)
LP-50:
use LP-50 printer
AUTO
Prt 1
print out format 1
Prt 2
print out format 2
Prt 3
print out format 3
Prt 4
print out format 4
Prt 5
print out format 5
calibration
UnLoad → select the calibration weight → Load → complete
Baud value
Select 1200/2400/4800/9600
Gravity value
Language, select (English/Chinese)
key to ensure, or press the
key to begin.
key to continue to the next parameter and
key to store the value. The display will go back to the
d (high division)
1 kg
0.5 kg
0.5 kg
2 kg
1 kg
1 kg
5 kg
2 kg
2 kg
5 kg
2 kg
2 kg
10 kg
5 kg
5 kg
10 kg
5 kg
5 kg
20 kg
10 kg
10 kg
oFF (turn off unit kg)
oFF (turn off unit lb)
oFF (turn off unit tj)
oFF (turn off unit hj)
key to select " F 1 A20 ", press the
to the next parameter.
key to return to
0.2 kg
0.1 kg
0.5 kg
0.2 kg
1 kg
0.5 kg
1 kg
0.5 kg
2 kg
1 kg
2 kg
1 kg
5 kg
2 kg
STD
DEFULT
VALUE
Low
AZ 2d
5000 kg
bk AU
oFF 0
Auto
9600
English