Mounting conditions
Mounting place
Mounting position
Free space
4.2
Rated data
Mains
3/PE AC
3/PE AC
3/PE AC
E94AZMR0264xDB
E94AZMR0474xDB
 Temperature in the control cabinet
E94AZMR0264SDB
E94AZMR0264LDB
E94AZMR0474SDB
E94AZMR0474LDB
EDK94ZMR47XDB DE/EN/FR/ES/IT 4.0
In the control cabinet
Vertically
The required free space results from the mounting position
and the specifications of the standard device.
Voltage
Voltage range
U
[V]
U
Lrated
230
180 − 0 % ... 264 + 0 %
400
320 − 0 % ... 440 + 0 %
500
400 − 0 % ... 550 + 0 %
Voltage
Frequency
[V]
[Hz]
230/400/500
50/60
230/400/500
50/60
Power loss
Inductance
P
[W]
L [mH]
V
65
0.77 ±10 %
72
85
0.42 ±10 %
101
l
Technical data
Rated data
[V]
Lrated
45 − 0 % ... 65 + 0 %
45 − 0 % ... 65 + 0 %
45 − 0 % ... 65 + 0 %
Rated current [A]
up to +45 °C 
up to +55 °C 
26/26/26
19/19/19
47/47/47
35/35/35
Regenerative
inductance
L
[mH]
gen
0.84 ±10 %
1.54 ±10 %
4
Frequency range
f [Hz]
Number of
phases
3
3
Voltage drop
DU [V]
6.3
6.2
37