Electrical installation

6.1
Important notes
Installation must
ƒ
– always be in accordance with the operating conditions specified in the Technical
data (¶ 36).
– be carried out to EN 60204−1.
Please observe the following when selecting the cable type:
ƒ
– The cables used must comply with the approvals required for the application (e. g.
VDE, UL etc.).
– Fuses and cable cross−sections must be dimensioned in accordance with the
specifications in the documentation for the basic device.
The described EMC properties are provided if the following conditions are complied
ƒ
with:
– The devices are mounted according to the arrangement concept described.
– The prepared cables are used and remain unchanged.
{
Danger!
Dangerous electrical voltage
All power terminals remain live for up to three minutes after mains
disconnection.
Possible consequences:
ƒ
Protective measures:
ƒ
ƒ
EDK94ZMR47XDB DE/EN/FR/ES/IT 4.0
Death or severe injuries when touching the power terminals.
Switch off the power supply and wait for at least three minutes before
working on the power terminals.
Make sure that all power terminals are deenergised.