MANOMETER M1 : BOILER PRESSURE
The boiler pressure is adjusted in factory between 0,8 MPa (12 PSI) and 1 MPa (15 PSI). This value
varies slightly around its nominal temperature, due to the PID system which controls the heating and
limit the current consumption to its minimum.
NOTE: An over-heating thermostat will cut the heating, in case of an abnormal high temperature.
MANOMETER M2 : PUMP PRESSURE
The pump pressure is adjusted at 9 MPa in the factory. Value which allows the best extraction of
coffee flavors. A bypass system evacuates over-pressure.
NOTE: Simultaneous operation of all the groups can impact a little bit the pressure level.
Visualization of the presence of water network is done by consulting the gauge
22.2.
Simply select one of the buttons available on each keypad to obtain the doses or the
programmed drinks.
The selected dose is shown by a blinking led on the keypad.
The flow can be stopped by repressing:
o The same button or
o The STOP button (which is also the programming and continuous flow button).
Edition 05/2015 - CC100 DISPLAY- TECHNICAL DOCUMENTS - page 37
SACOME, CONFIDENTIAL Document,
HOW TO USE THE PROGRAMMED DOSES
it is forbidden to duplicate or communicate this document without previous authorization.