Max. 250 V / 16A
External alarm
Dry contact NO
7. OPERATION OF THE ALARM UNIT
For wall mounting of the unit, use the following image as a guide (in mm) :
The SANICOM® alarm unit does not require a separate power supply. The
power is supplied through the SANICOM®. In case of power failure, the alarm
unit's battery takes over.
Connection of the alarm unit to the device : Connect the alarm cable directly
to the unit.
Red LED :
alarme
1/ The red general alarm LED reproduces the operation of the corresponding
LED on the SANICUBIC® control panel. The alarm unit sounds as long as the
fault is present. To stop the alarm, press the reset (*) button on the device's
keypad or the button under the alarm unit.
2/ The yellow «mains» LED indicates the power supply status of the alarm unit :
- steadily glowing light = live SANICOM® connected to the mains supply
- flashing = power failure on the SANICOM®.
8. STANDARD
This piece of equipment complies with the EN 12050-2 standard (Lift station for
effluents not containing faecal matter) and European Low Voltage Directive.
9. INSPECTION AND MAINTENANCE
1/ Inspection
The proper running of the wastewater lifting station must be checked by user
once a month observing at least two starting cycles.
2/ Maintenance
The lifting station has to be regularly maintained by a qualified person.
Intervals should:
- Every 3 months for lifting stations installed in commercial premises
- Every 6 months for lifting stations installed in collective buildings
- Once a year for lifting stations installed in individual houses
During maintenance, the following should be done:
a) Check the watertightness of connections by checking pipework to and from
the lifting station
b) Activate the gate valves, check their smooth function and their
watertightness ( grease if necessary)
Alarm contact can be connected
to a powered system. This
contact closes as soon as the
station is in alarm mode (except
in the case of area alarm) and
remains closed as long as the
alarm sounds.
(SANICOM® 2)
Yellow LED :
mains supply
(*) Reset
11
c) Open and clean up the non return-valve system, check it is functioning
correctly
d) Clean up the pumping system and its connections, check the impeller and
the cutting system (for macerating pumps)
e) Clean up the inside of the collecting tank
f ) Visually check the lifting station's electrical control box functions.
Once the checks have been made, restart the lifting station in compliance
with the manual instructions to check its proper running.
A report should be issued detailing the checks and any notable points.
If non-compliances that cannot be solved have been found, the qualified per-
son in charge of the maintenance work has to immediately inform the lifting
station's user.
3/ Maintenance contract
It is advised to the users to establish a maintenance contract for regular main-
tenance and checking.
10. FAULT FINDING GUIDE
DISCONNECT THE STATION BEFORE ANY
INTERVENTION !
Alarm on SANICOM® 1 device :
FAULT DETECTED
POSSIBLE CAUSES
Flashing red alarm LED
• Water level detection
system faulty
Steady red alarm LED
• Blocked vent pipe
• Blocked discharge
• Blocked pump or out
of order
• Discharge too high or
excessive inflow
LED off
• Power outage
• Faulty printed circuit
board
Alarm on the SANICOM® 2 control box :
FAULT DETECTED
POSSIBLE CAUSES
Siren + flashing red
• Water level detection
general alarm LED
system faulty
Siren + steady red
• Blocked vent pipe
general alarm LED
• The device has
encountered the following
problem: blocked pipe,
pump(s) blocked
• The device has
encountered a power
failure
Siren + general alarm
• Mains cut
LED + flashing yellow
mains LED
11. DISMANTLING
INSTRUCTIONS RESERVED EXCLUSIVELY FOR QUALIFIED
PROFESSIONAL SPECIALISTS
If one of the motors cannot be made to operate correctly, use
of that motor can be "disabled" by setting the corresponding
switch on the board (P1, P2 : Switches 1 and 2 for motors 1 and
2).
The motor thus "disabled" can be removed. The unit operates
on the other motor.
12. GUARANTEE
2 years guarantee as from its date of purchase subject to correct installation
and correct use.
Any damage due to foreign bodies such as cotton, condoms,
sanitary towels, wet wipes, food, hair, metal, wood or plastic
objects, will not be under guarantee. Solvents, acids and other
chemicals can also cause damage to the unit, and will invalidate
the guarantee.
UK
ACTION TO BE TAKEN
• Consult SFA after-sales
service
• Check that air flows
freely in both directions in
the vent pipe
• Review installation
• Consult the SFA
customer services
• Check the electrical
system
• Consult the SFA
customer services
ACTION TO BE TAKEN
• Consult the SFA
customer services
• Check that air flows
freely in both directions in
the vent pipe
• Press the manual start
button to reset the device
(alarm off )
• Consult SFA customer
services
• To stop the siren, press
on the Force Start button
• Check the electrical
system
• Consult the SFA
customer services