- Do not switch on the dimmer if the transformers are not loaded.
- The select key cannot be controlled by means of a sharp object.
- If the foil on the front is damaged, you are strongly advized to
replace the dimmer.

7. TECHNICAL DATA

- Power supply: 230V ±10%, frequency 50Hz
- Installation: DIN rail (2U)
- Weight: ±144g
- Allowed ambient temperature: see load table
- Designed for use in an environment with a non-condensing
atmospheric humidity (30% - 70%)
- Own consumption: ±1W
- Max. enclosure temperature (tc): 90°C
- Max. wire diameter per terminal:
- power supply and load: 1 x 2.5mm
- input: 1 x 2.5mm
- Minimum load: 60W
- Maximum load: 750VA resistive, inductive and capacitive
(t°<35°C)
- Maximum voltage drop across dimmer: -5%
- Protections: - electrical, thermal protection (105°C) with
- Complies with standards EN60669-2-1 and EN55015
- Maximum distance to last push-button: 100m
- Max. output voltage: supply voltage x 0.95 (dissipated power
= max. 1% of absorbed power = max. 7W)
EN
or 2 x 1.5mm
2
automatic reinitialization (light is automatically
dimmed). If the temperature does not drop, the
load is switched off.
- Single thermal overload protection (135°C)