The wired control has 4 operating modes and is connected to
terminals 1 and 3 of the 'control terminals' (fig. A). The operating
modes are:
- 1-button mode with push buttons
- calling up/programming a light atmosphere with push buttons
- OFF with 3-second operating time with push buttons
- OFF with time delay (run time) with push buttons
The power supply is connected to the 'connection terminal power
supply 230V~', between terminals L and N. For the wiring diagrams,
see at the back of this manual.
In case of poor reception by the wireless control, you can connect
an antenna 05-309 to "Connector for external antenna 05-309"
(fig A and fig.3)
➊ load terminals (N,
➋ terminals power supply 230V~ (L, N)
➌ load LED
➍ error indication LED
➎ RF reception LED
➏ select button
➐ control terminals
(terminals 1 up to and incl.3)
➑ connector for external antenna 05-309