05-353
B. Reinitializing the dimmer in reversed phase control
When connecting a new load (e.g. use of low-voltage halogen
instead of incandescent lamps) it is advisable to reinitialize the
dimmer. Press and hold down the 'select' button when
switching
on the supply voltage.
The dimmer will return to the standard mode, i.e.
reversed phase control.
All LEDs will blink for approx. 10s by way of confirmation.
4. OPERATION
A. Operation in the various modes
Mode 1: 1-push button operation with/without memory
In mode 1, you can set the push button so that dimming with or
without memory is possible. The default setting of the dimmer
is with memory. (see fig 1)
Switching the memory function
To set up the dimmer "without" memory function: set the dimmer
to its maximum output voltage and press the "select" key for 10s
until the "beep" tone stops.
Repeat the procedure to reactivate the memory function. This
function will be saved in a permanent memory. The most recent
light setting will be lost in the event of a power failure.
With memory function, the dimmer first switches on at the min.
light level. There after the dimmers switches on at the last set
value.
58
EN