Figure 3
1. Push the fuse holder with the red wire into fuse
number 20.
Is there a Fuse in Place use place number 7 or 8. In
case there is also a fuse lower or greater than 10amp
in place pull this fuse out and push it in to the fuse
holder on the harness instead off the 10amp fuse.
Figure 4
1. Release connector -1 and pull it off onboard supply
control unit (also known as Body Control Module in USA)
(BCM -J519-).
2. Release connector housing and slide open upper part.
3. Insert yellow wire of wiring harness into chamber C54 of
connector.
Note
If chamber C54 is already in use, unpin wire and insert it
into connector housing supplied and connect to connector.
Then insert yellow wire of wiring harness into chamber C54.
4. Insert connector into onboard supply control unit (also
known as Body Control Module in USA) (BCM -J519-)
and lock.
Installing and connecting window aerial
Figure 5
Note
The temperature required when bonding the window must
lie between 18 – 40°C (64 – 104°F). The glass in the area
of the bonding point must be dry and free of dust and
grease.
1. Thoroughly clean bonding point -a- on right, next to
mirror base with the cleaning cloth supplied.
The driver's fi eld of view must, under no
circumstances be restricted.
2. Bond aerial -1- on right next to mirror base, as shown.