Chapter 6. Machine adjustment and setting up
DIAGNOSTIC MENU
-> UTILITY
-> STATUS
-> ALARMS
-> OUTPUTS
-> INPUTS
Press the button (S).
DIAGNOSTIC MENU
-> UTILITY
-> STATUS
-> ALARMS
-> OUTPUTS
-> INPUTS
Press the button (▼) to
switch to STATUS function.
Now press the button (S).
DIAGNOSTIC MENU
-> UTILITY
-> STATUS
-> ALARMS
-> OUTPUTS
-> INPUTS
Press the button (▼) to switch to
ALARMS function.
Now press the button (S).
DIAGNOSTIC MENU
-> UTILITY
-> STATUS
-> ALARMS
-> OUTPUTS
-> INPUTS
Press the button (▼) to switch to
OUTPUT function.
Now press the button (S).
DIAGNOSTIC MENU
-> UTILITY
-> STATUS
-> ALARMS
-> OUTPUTS
-> INPUTS
Press the button (▼) to switch to
INPUTS function.
Now press the button (S).
UTILITY
Config. Lock: NO
-> RESET TO DEFAULT
Once the parameters have been changed press the stop button
(5) to return to the DIAGNOSTIC MENU.
STATUS
Cycles:
000000
Oil:
12000
Stop:
000000
On time:
000000
Cycle time: 000000
Warranty: 01/01/11
Press the stop button (5) to return to the
DIAGNOSTIC MENU.
ALARM
Gas pressure:
OK
Vacuum time:
OK
Soldering time:
OK
Pump time:
OK
Press the stop button (5) to return to
the DIAGNOSTIC MENU.
OUTPUT
Vacuum valve:
[
]
Air valve:
[
]
Gas valve:
[
]
Soldering valve:
[
]
Soft-air valve:
[
]
Vacuum pump:
[
]
Press the stop button (5) to return to the
DIAGNOSTIC MENU.
INPUT
Microswitch:
OFF
Pressure switch: OFF
34
NO: the configuration is not blocked. All set
parameters can be changed.
YES: the configuration is blocked. None of the
parameters can be changed.
Allows restoring default values
The following are displayed:
Total number of cycles performed by machine.
Number of cycles after which the OIL alarm trips.
Number
of cycles after which the machine can be blocked.
Total number of hours of activity of machine.
Total number of machine cycle hours.
End of machine warranty.
The state of the alarms is displayed:
OK: Correct operation
AL: Alarm tripped due to fault.
The correct operation of the outputs can be checked
as follows:
Using the buttons (▼) and (▲) position the cursor
on each output and press the button (►).
[
X
] appears and, if correctly operating, you will
hear the contact of the diagnosed output open.
Press the button (◄ ) to close the contact.
The correct operation of the inputs can be checked
as follows:
Press the lid micro contact and/or disconnect the
pressure switch.