Chapter 6. Machine adjustment and setting up

6.1. Adjustment

6.1.1. Control panel

The machine is fitted with a control panel, from which all programming and operation functions can be set.
Q1: Main switch
P:
Label printer
1:
Led for vacuum and extra vacuum function
2:
Led for gas function
3:
Led for sealing function
4:
Led for air re-immission function
5:
Stop button
6:
Confirmation button
7:
Selection button
8:
Selection button
9:
Setting button
10: Setting button
11: Display

6.1.2. Switching the machine on

Set the main switch (Q1), located on the rear of the machine, to ON.
The display screen switches on and after the Minipack-torre logo, the following display page appears:
MINIPACK-TORRE
www.minipack-torre.it
Rev : 00.02.000
Language:
< EN >
PROGRAM:
Time:
Vacuum limit:
Vacuum:
Residual:
Extra-vacuum:
Gas ratio:
To switch from one function to another, press the adjustment buttons
The selected function is dimmed; at this point, to change the settings, press the buttons
Before starting to pack, the program must be selected and the variable must be set according to the product
to be packed.
To do this, follow the instructions provided below.
If the language to be set is different from that displayed, press the button ( ►) and
select the required language.
Wait for the next display page "CONFIGURATIONS" and the main display page shown
below to scroll.
If instead the language is correct, wait for the main display page to appear.
displays the active program no. (P01÷P10).
displays the sealing time set.
displays the degree of vacuum required inside the pack.
displays the "vacuum state" in the packaging chamber during the vacuum stage.
displays the difference between the set vacuum limit and the current level.
indicates how long the pump continues to extract air from inside the bell after the
machine has achieved the set vacuum level.
displays the percentage of gas inside the package.
(▲)
(▼)