Cleaning the inlet hose and the valve filter
1.
1
2
3
Frost precautions
If the appliance is installed in an area
where the temperature can be less than
0°C, remove the remaining water from the
inlet hose and the drain pump.
Do this procedure also when
you want to do the emergency
drain.
1. Close the water tap.
2. Remove the water inlet hose.
3. Remove the drain hose from the rear
support and unhook it from sink or
spigot.
4. Put the ends of each drain and inlet
hose in a container. Let the water flow
out of the hoses.

TROUBLESHOOTING

WARNING! Refer to Safety
chapters.
Introduction
The start of the appliance does not occur
or it stops during operation.
First try to find a solution to the problem
(refer to the table). If not, contact the
Authorised Service Centre.
2.
5. Set the Vidange programme and let it
operate until the end of the cycle.
6. Turn the programme knob to position
7. Disconnect the appliance from the
mains socket.
The red indicator of button Départ/Pause
flashes.
3.
to deactivate the appliance.
WARNING! Make sure that the
temperature is more than 0°C
before you use the appliance
again. The manufacturer is not
responsible for damages
caused by low temperatures.
WARNING! Deactivate the
appliance before you do the
checks.
4.
90˚