WARNING! Make sure that the impeller of the pump can rotate. If it does not
rotate, contact the Authorised Service Centre. Make sure also that you
tighten the filter correctly to prevent leakages.
Cleaning the inlet hose and the valve filter
3
Emergency drain
If the appliance cannot drain the water,
carry out the same procedure, described
in 'Cleaning the drain pump' paragraph. If
necessary, clean the pump.
Frost precautions
If the appliance is installed in an area
where the temperature can reach values
around 0° C or drop below, remove the
remaining water from the inlet hose and
the drain pump.
1. Disconnect the mains plug from the
mains socket.
TROUBLESHOOTING
WARNING! Refer to Safety
chapters.
1
2
20°
2. Close the water tap.
3. Put the two ends of the inlet hose in a
container and let the water flow out of
the hose.
4. Empty the drain pump. Refer to the
emergency drain procedure.
5. When the drain pump is empty, install
the inlet hose again.
WARNING! Make sure that the
temperature is higher than 0 °C
before you use the appliance
again.
The manufacturer is not
responsible for damages
caused by low temperatures.
45°
29