Télécharger Imprimer la page

DJO ARTROMOT-K1 Standard Mode D'emploi page 55

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 70
LEVEL :
n Extension stretching
− Maximum knee extension:
− Maximum hip extension:
n Flexion bending
− Maximum knee flexion:
− Maximum hip flexion:
Note!
The programmed value and the value
measured at the patient's knee may
differ slightly.
n Speed
The speed can be adjusted in steps of %
between % and
%.
Default setting:
%
n Warm up protocol
During warm up, the patient will slowly
become used to the set maximum ex
tension and flexion values, starting from
the center position.
The warm up protocol starts in the mid
dle between the two maximum values
set for stretching and bending. The range
of motion increases with each cycle, until
the programmed maximum values are
reached after a total of
Default setting: disabled
LEVEL :
n Extension pause
Pauses occur at the set extension limit,
just before the bending movement
starts. Pauses can be set to any value
between
and
seconds in steps of
second, and to values between and
minutes in steps of minute.
Default setting: no pause
n Flexion pause
°
°
°
n Timer therapy time
°
n Reverse on load
cycles.
Pauses occur at the set flexion limit, just
before the stretching movement starts.
Pauses can be set to any value between
and
seconds in steps of second,
and to values between and
in steps of minute.
Default setting: no pause
Default setting is continuous operation.
A clock symbol in the upper right hand
corner of the display identifies the con
tinuous mode of operation. The clock
indicates the elapsed therapy time. In
the continuous mode, the device must
be stopped with the STOP button.
However, you can also select therapy
durations of to
minutes in steps of
minute and of to
minutes.
When the time has elapsed, the unit
switches automatically off and stops
in the position equivalent to the set
extension value + °. In this case, a circle
replaces the clock symbol. The circle fills
as the therapy time progresses.
safety function
The device automatically starts moving in
the opposite direction of the last move
ment when the patient's resistance load
exceeds the set value. Adjustable levels
for reverse on load feature:
level , very low resistance will cause the
device to reverse; at level
tance is required to initiate the reversal.
Default setting: Level
Caution!
Patient hazard
The reverse on load feature is only a
safety measure in the event of cramps,
spasms, locked joints and similar condi
tions. The manufacturer cannot be held
liable for misuse of this feature.
minutes
hours in steps of
. At
, a high resis

Publicité

loading