4-5 Device Settings
5. Modem Server IP Address
This IP address will be assigned to the RIPM itself during the PPP handshake.
Since it is a point-to-point IP connection, virtually any IP
address may be assigned, but you must make sure that it does not
interfere with the IP settings of the RIPM and your console computer.
The default value will work in most cases.
6. Modem Client IP Address
This IP address will be assigned to your console computer during the PPP
handshake. Since it is a point-to-point IP connection, virtually any IP
address may be assigned, but you must make sure that the assigned IP is not
interfering with the IP settings of the RIPM and your console computer. The
default value will work in most cases.
7. Pass-Through Access to Serial Port via Telnet
Using this option, it is possible to connect an arbitrary device to the serial port
and access it (assuming it provides terminal support) via Telnet. Select the
appropriate options for the serial port and use the Telnet console or a standard
Telnet client to connect to the RIPM. For more information about the Telnet
interface, refer to the "Telnet Console" section.
Note: Check www.belkin.com for a list of compatible modems.
61
P75075ea_F1DE101Hea_man.indb 61
Menu Options