Menu list

Complete keyboard configuration is reassumed in the following table.
Take care to avoid miscomprehension in changing parameters.
* :critical parameters, which can prevent the connection between video matrix and keyboard if wrongly set.
Menu
1.Language
2.Matrix setup *
2.1 Type *
2.2 Communications *
2.3 Baudrate *
3. <not used>
4. Communication channel test
4.1 Matrix Channel
4.2 Automatic Matrix Channel
5. Enablings
5.1 Inputs
5.2 Outputs
5.3 Keys (Up/Down)
5.4 Other parameters
6. Password *
6.1 Connection Password *
6.2 Alarm Reset Password
6.3 Setup Password *
7. Operator identification number
8. Buzzer
Meaning
Menu language
Connected matrix features
Type of video matrix
Communication mode
Baudrate (only for OSM matrix).
Connection test procedures
Connection matrix test
Automatic connection matrix test, by using RJ
junction box
Enabled inputs, outputs, and up/down keys:
user-defined
Every input can be enabled/disabled: disabled
inputs are not selectable directly from the
keyboard; they are visible only in case of alarm
or if included in switching cycles.
Selection of available outputs for video
switching.
Key locking is used when an operator isn't
allowed to manage completely keyboard
function because of securecy reason.
Click: when enabled, a sound confirms the
pressed key. Messages: when enabled, error
and warning messages are shown.
Password management.
NB: passwords are private for each operator:
they can be different in each single keyboard.
Requested when the keyboard is powered up
to avoid the use by unauthorized personnel.
Requested when an alarm condition is going to
be reset.
Requested when configuring the keyboard or
the matrix.
If the controlled matrix is SW164OSM
Standard, it is necessary to identify all 4
operators
by a different identification number each.
Buzzer can be activated on alarm condition or
communication fault.
Page 10
Selectable values
english (default),
italian, french,
german, spanish
SW164
Standard (default) or
OSM
RS232 (default) /
Current Loop
300, 1200, 2400,
9600 (default) baud
Default: all inputs are
enabled
Default: all outputs
are available.
Default: all keys are
enabled
Default: disabled
(000000)
Default: disabled
(000000)
Default: disabled
(000000)
Default:
operator no. 1.
Default: enabled only
in case of alarm.
KEYPLUS9702