Password management

Problem
The operator wants to prevent unauthorized
personnel from having access to the keyboard.
The passwords of the keyboards are different,
even if they are all connected to the same matrix.
The passwords of a
forgotten or lost.
The operator wants to disable a password.

SW164OSM Standard matrix programming

Problem
The preset sequence cycles do not work as
expected.
The time/date parameters have been set
correctly but the matrix always shows the night
sequence.
SW164OSM matrix programming
Alarms
Problem
After having configured the alarms, the matrix
exits from the programming mode and gives
immediately an alarm signal even if no alarm
contact has been activated.
Closing a contact, the relevant alarm does not
activate.
The alarm ceases automatically without the
intervention of the operator.
Other options
Problem
The text on the menu output is considerably
shifted upwards.

Specifications

190 x 55 x 185 mm
Dimensions:
980 g
Weight:
keyboard have been
Possible cause
Wrong
time/date
matrix is showing the night
sequence.
Some days of the week have
been defined as holidays
during the matrix setup by
means
Computer.
Possible cause
During the setup phase, the
connection
password
been disabled.
The passwords are "local"
and
stored
into
keyboard.
-
-
setting
of
parameters:
of
Personal
Possible cause
During the matrix setup,
some alarm contacts have
been defined as Normally
Closed.
The
contact
has
defined as Not Used
The time reset has been
activated
or
the
alarm
signals have been defined
as "Continuous signals"
Possible cause
The NTSC video system has
been set.

Power supply specifications

Input voltage:
Output voltages:
Connector:
pin 1-3: 9V
pin 2-4: 14V
Page 23
Remedy
During the setup phase, set the
has
connection password to a different
value from 000000.
Set
(if
necessary)
the
passwords for all keyboards.
Please contact the supplier
Set it to 000000. Note: for safety
reasons, we recommend setting at
least the setup password.
Remedy
the
Check if the set time and the
the
start/end of the day sequence have
been set correctly.
Redefine all days of the week as
working days during the setup by
means of PC; for further information
please contact the supplier.
Remedy
Close
the
contact
contact by means of the alarm
common wire) or define it as
Normally Open.
been
Activate the contact as Normally
Open or Closed
Set the correct reset options.
Remedy
In the menu 4. System parameters
set the PAL video system.
230V~ 50Hz 30VA
9V~ 50HZ 8VA
14V~ 50HZ 8VA
Mini Din 4 poli
~
~
the
same
(short
the
KEYPLUS9702