Troubleshooting; Technical Data - VOLTCRAFT VC930 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

14. TROUBLESHOOTING

In purchasing the DMM, you have acquired a product designed to the state of the art and operationally reliable.
Nevertheless, problems or errors may occur.
For this reason, the following is a description of how you can easily remove possible malfunctions yourself:
Always observe the safety information!
Repairs other than those described above must only be carried out by an authorised specialist. If
you have any questions about handling the meter, our technical support is available under the fol-
lowing telephone number:
VOLTCRAFT®, 92242 Hirschau, Lindenweg 15, Phone No. +49 (0) 180 / 586 582 7.

15. TECHNICAL DATA

Display
Measuring rate
Measuring line length
Measuring impedance
Operating voltage
Working conditions
Operating altitude
Storage temperature
Weight
Dimensions (LxWxH)
Over-voltage category
5
VC930
Max. 40,000 counts
3 measuring operations/second
approx. 90 cm each
10MΩ (V range), <100pF
4 mignon batteries (type AA)
11 to 30°C (<80%rF), >30 to 40°C (<75%rF), >40 to 50°C (<45%rF)
max. 2,000 m
-20°C to +60°C
approx. 620 g
212 x 98 x 52 mm
CAT III 1,000 V, CAT IV 600 V, contamination degree 2
VC950
Max. 100,000 counts

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vc95012 47 0312 47 05

Table des Matières