Alternating current
Range
40.000 mA
± (1% + 80) at 40Hz ~ 65Hz
400.00 mA
± (3.9% + 80) at 66Hz ~ 1KHz
4.0000 A
10.000 A
Impedance
Range
400.00 Ω
4.0000 kΩ
40.000 kΩ
400.00 kΩ
4.0000 MΩ
40.000 MΩ
Overload protection 1,000 V; Measuring voltage: approx. 2.5 V
Capacity
Range
40.00 nF
400.0 nF
4.000 µF
40.00 µF
400.0 µF
4.000 mF
40.00 mF
Overload protection 1,000 V
Frequency
Range
40.000 Hz
400.00 Hz
4.0000 kHz
40.000 kHz
400.00 kHz
4.0000 MHz
Overload protection 1,000 V
Sensitivity (40 Hz – 40 kHz): 1 Veff (rms)
Sensitivity (400 kHz – 4 MHz): 5 Veff (rms)
60
VC930
Accuracy
VC930
Accuracy
± (0.3% + 30)
± (0.4% + 30)
± (1.3% + 30)
± (1.95% + 30)
VC930
Accuracy
± (1.6% + 20)
± (1.2% + 2)
± (1.6% + 20)
± (1.6% + 40)
VC930
Accuracy
± (0.003% + 50)
± (0.003% + 10)
Range
10.0000 mA
± (0.91% + 80) at 40Hz ~ 65Hz
100,000 mA
± (2.6% + 80) at 66Hz ~ 1KHz
10.0000 A
Range
1000.00 Ω
10.0000 kΩ
100.000 kΩ
1000.00 kΩ
10.0000 MΩ
40.000 MΩ
Range
40.00 nF
400.0 nF
4.000 µF
40.00 µF
400.0 µF
4.000 mF
40.00 mF
Range
40.000 Hz
400.00 Hz
4.0000 kHz
40.000 kHz
400.00 kHz
4.0000 MHz
VC950
Accuracy
VC950
Accuracy
± (0.07% + 30)
± (0.033% + 30)
± (0.39% + 30)
± (1.3% + 30)
± (1.95% + 30)
VC950
Accuracy
± (1.6% + 20)
± (1% + 2)
± (1.6% + 20)
± (1.6% + 40)
VC950
Accuracy
± (0.003% + 50)
± (0.003% + 10)