Télécharger Imprimer la page

Videotec WASPT Serie Manuel D'instructions page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
6 Installation
Install the pump with 30m (98ft) pressure
head in places protected from heavy rain.
The device should be assembled vertically.
Any other position could impair the
performance of the device.
6.1 Fastening of the metal cage
Take special care when attaching and
fastening down the apparatus. If it is to
be attached to a concrete surface you
must use dowel pins with a traction
torque rating of at least 0.4kN each. You
are advised to use screws with a 6mm
diameter and at least 50mm long. If the
surface is metal, use M8 class A4-70 screws
and with such a length to guarantee at
least 6 rotations of the held thread. The
fastening system must be capable of
supporting at least 4 times the weight of
the entire equipment, including the tank
completely full of water.
For the version with 5 litre tank only,
fastening is possible on a pole using the
specific accessories.
Fig. 2
MNVCWASPT_2222_EN
Take the plug out of the tank, along with any pumps
and level gauges. Remove the tank from the metal
cage.
Attach the metal cage (01) firmly to a wall using the
holes provided for this (02).
Fig. 3
Water tank 5l (1.3gal), 5m (16ft) delivery.
Fig. 4
Water tank 23l (6gal), 5m (16ft) or 11m (36ft) delivery.
Fig. 5
Water tank 23l (6gal), 30m (98ft) delivery.
01
02
01
02
01
02
7

Publicité

loading