6.5 Connection of the board
Electrical connections must be performed
with the power supply disconnected and
the circuit-breaker open.
6.5.1 Installing the fuse
6.5.1.1 Pump with 5m (16ft) or 11m (36ft)
delivery
Depending on the power supply voltage
choose the right fuse holder.
The board is supplied with the fuse in the following
position: FUS1, 230Vac (6.4 Board description, page
8).
6.5.1.2 Pump with 30m (98ft) delivery
Depending on the type of power supply, the board is
supplied with the fuse in the correct position: FUS1,
230Vac or FUS2, 120Vac (6.4 Board description, page
8).
MNVCWASPT_2222_EN
6.5.2 Connection of the PTZ camera or
stand-alone housing
All the connections of terminal J9 must
have very low safety voltage (sources of
electrical energy class 1 (ES1)).
The AVL, GND, A1L and A2L contacts can
only be used in pump models equipped
with floats. If active, the AVL alarm
supplies an output voltage between 12Vdc
and 20Vdc.
Contacts rated current: 4A max.
Fig. 8
Connect the PTZ camera or the stand-alone housing
to the terminal contacts (J9, 6.4 Board description,
page 8).
For connection, use the table outlined below as a
reference.
Nominal section of the cables used: from
0.5mm² (20AWG) up to 1.5mm² (15AWG).
J9
A B
RS485