CV Explanation
1
Address 1 (main address)
2
Minimum speed (Vmin)
3
Acceleration delay (AV)
4
Braking delay (BV)
5
Maximum speed (Vmax)
7
Automatic Calibration
8
Decoder reset (default or factory setting)
17
Address 3 (2nd consecutive address)
18
Address 4 (3rd consecutive address)
Braking mode:
27
Bit 4 : DC voltage, polarity against the direction of travel
Bit 5 : DC voltage, polarity with the direction of travel
Configuration:
Bit 0: Reverse the locomotive's direction properties
29
Bit 1: number of speed levels (14 or 27)
Bit 2: turn analog operation on/off
Expanded configuration:
Bit 0: number of addresses, LSB
49
Bit 1: number of addresses, MSB
Bit 2: automatic consecutive addressing
28
CV Table for fx (MM)
Values
Default Notes
0-255 (1 - 80)*
78
0-255 (1 - 80)*
4
0-255 (1 - 80)*
12
0-255 (1 - 80)*
12
0-255 (1 - 63)*
180
{x4}*
77
8
0-255 (1 - 80)*
254
0-255 (1 - 80)*
253
16
48
32
0 - 7
6
0 - 7
5
CV value multiplied by 0.25 gives the time from
complete stop to maximum speed.
CV value multiplied by 0.25 gives the time from
Maximum speed to complete stop.
Address can be deactivated/activated subject
to CV 49.
Braking subject to direction:
- 16 normal DCC properties
- 32 inverse DCC properties
Braking not subject to direction:
- 48: fx/mfx properties
The direction properties refer to the direction of
travel and the lights.
0 = one | 1 = two | 0 = three | 1 = four
0 Add. | 0 Add. | 1 Add. | 1 Add.
0 = auto. sequence on / 1 = auto. sequence off

Publicité