Audio Continuity Test - Chauvin Arnoux F 03 Notice De Fonctionnement

Pince multimètre
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
MIN/ MAX Mode:
- Accuracy: ditto preceding table + 0.2% L
- Capture time: 100 ms typ.
PEAK Mode:
- Accuracy: ditto preceding table +2% L
- Capture time: 500 µs typ. (2.5 ms max.)
Special characteristics in V-Live mode
- Detection threshold accuracy: 45 V

3.3 Audio continuity test (

1. Connect the measuring leads to the instrument's terminals.
2. Set the selector switch to the "
3. Connect the instrument to the circuit to be tested. The
buzzer is permanently active as soon as contact is
established (circuit closed) and if the value of the resistance
measured is less than the value of the threshold chosen
by programming (can be set from 1 to 40 Ω, see § 3.8.11)
Above 400 Ω, the display indicates " OL ".
Offset of measurement lead resistance (zero Ω Ω Ω Ω Ω )
To measure low-value resistance, first measure the
resistance of the leads.
- Short-circuit the leads.
- Press on the HOLD key and hold down until zero is
displayed. The value of the resistance of the leads will
then be saved and deducted from the value of the
resistance subsequently measured.
Note: If the value measured is over 2 Ω , this correction is
inhibited and the value of the correction saved is
reset to zero.
Characteristics
Display range
Measuring range
Accuracy (1)
Resolution
Open circuit voltage
Measuring current
Protection
(1) with offset of the resistance of the measurement leads
MIN/ MAX Mode:
- Accuracy: ditto preceding table + 0.2% L
- Capture time: 100 ms typ.
± 2V.
peak
)
" position.
400 Ω
0.0 to 399.9 Ω
1% L +2 counts
0.1 Ω
≤ 3.2 V
320 µA
500 V AC or 750 V (DC or peak)
28
28

Publicité

Table des Matières
loading

Table des Matières