Resistances (Ω); Continuity Sound Test; General Specifications - Chauvin Arnoux C.A 5001 Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
6 - RESISTANCES
Never test a resistance on a live circuit.
I Zero reset - Connect the leads to the multimeter.
Place the selector switch on the appropriate Ω range.
Short-circuit the test prods and bring the needle to 0 on the green
Ω scale by using the zero reset potentiometer.
The power supply of the ohmmeter is provided by a 1.5 V
battery. If the zero reset can not be done replace the battery.
I Connect up to the terminals of the circuit or the component to test.
I To get the resistance in Ω, multiply the reading on the the Ω scale
(green) by the coefficient of the selected range: x 1 or x 100
(1)
Ω Ω Ω Ω
x1
Measurement
5 Ω to
extent
10 kΩ
Internal
140 Ω
resistance
End of scale
10 mA
current
(2)
10 %
Accuracy
Permitted
440 V
overload

7 - CONTINUITY SOUND TEST

I Connection and specifications: idem Resistances
I Place the selector switch on the
I Continuous audible beep emitted for a resistance R < 50 Ω

8 - GENERAL SPECIFICATIONS

8-1 Dimensions and weight
I 56 x 105 x 160 mm
8-2 Power supply
I One battery 1.5 V (type R6 or LR6 alkaline)
I Battery life: 10,000 measurements of 15 seconds with alkaline
battery.
x100
500 Ω
to 1 MΩ
(1) Common to the continuity
1400 Ω
sound test
(2) In % at mid-scale.
100 µA
x 1 function
I 500 g
15