Resistances (Ω); Continuity Sound Test; General Specifications - Chauvin Arnoux C.A 5005 Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
A~ with
3 A
miniclamp MN 89
Scale
(2)
3
Reading cœfficient
x 1
Accuracy
(3)
10%
Protection
(1) Range limitedto240AAC max by the miniclamp MN 89
(2) Marked with "
"
(3) In %ofthaend of scale
(4) Up to 200 A AC nominal range of the MN 89 miniclamp
(5) Measuring 240 A AC is equivalent to measuring 24 V DC
6 - RESISTANCES
Never test a resistance on a live circuit.
I Connect to the terminals of the circuit or the component to test.
If the "Voltest" light comes on, presence of a voltage U > 15 V
AC/DC. Unplug the leads immediately and cut off the voltage
before making the resistance measurement.
I To get the resistance in Ω, multiply the reading on the Ω scale
(green) by the cœfficient of the selected range: x 1 or x 100.
Measurement
extend
Internal resistance
End of scale current
(2)
Accuracy
Permitted overload
(1) Common to the continuily sound test function
(2) In % at mid-scale

7 - CONTINUITY SOUND TEST

I Connection and specifications: idem Resistances
I Place the selector switch on the
I Continuous audible beep emitted for a resistance R < 50 Ω

8 - GENERAL SPECIFICATIONS

8-1 Dimensions and weight
I 56 x 105 x 160 mm
10 A
30 A
100 A
10
3
10
x 1
x 10
x 10
5%
2.5%
(4)
ensured by the miniclamp MN89
x 1
(1)
x 100
5 Ω to
500 Ω to
10 kΩ
1 MΩ
140 Ω
14 kΩ
10 mA
100 µA
10%
440 V
x 1 function
I 500 g
(1)
300 A
3
x 100
(5)
15

Publicité

Table des Matières
loading

Table des Matières