Liquid crystal display
The liquid crystal display provides a digital display of the
values measured and the associated units and symbols.
Digital display
4 digits, 9999 points, 3 decimal points, + and - signs
(DC and peak measurement).
+ OL : Outside the range by a positive value (> 3999
points)
- OL : Outside the range by a negative value
OL
: Outside the range by a value without a sign
- - - - : Undetermined value (middle segments)
Display of symbols
+
Flashing, clamp autonomy limited to about 1
-
hour
Continuous, battery run down, the operation
or accuracy of the clamp cannot be
guaranteed
Constant operation (automatic shutdown
P
disabled)
Continuous: continuity measurement
Flashing: V-Live function selected
HOLD function active
HOLD
PEAK
Lit in V and A in MIN/MAX Mode if peak value
measurement is selected
MAX
Indicates the display of a maximum value in
MIN/MAX mode
MIN
Indicates the display of a minimum value in
MIN/MAX mode
AC
Continuous: measurement in manual AC mode
Flashing: measurement in automatic AC mode
DC
Continuous: measurement in manual DC mode
Flashing: measurement in automatic DC mode
Temperature measurement
INT
Measurement of temperature when the
terminals are not connected or the
thermocouple connected is faulty.