Télécharger Imprimer la page

Tuthill SOTERA SYSTEMS 400B Serie Manuel D'utilisation Et De Sécurité Du Propriétaire page 11

Publicité

Les langues disponibles

Les langues disponibles

Anti-Drip Nozzle Spout Kit
400KTF0237
For use with Norwesco and other nozzles
with a 1 - 3/16" outside diameter.
Installation
1. If there is a raised plastic notch on the nozzle,
carefully remove it with a file before installing the
Anti-Drip Spout.
2. Apply soapy water to the end to aid in the
installation. Place the Anti-Drip Spout on the nozzle
as shown. Tap the spout wih a rubber mallet until it
is fullt engaged. The space between the end of the
spout and the bend in the nozzle should be slightly
more than 1-3/4" when pressed fully into place.
Proper Use
1. Place the nozzle into the container to be filled
BEFORE turning the pump on.
2. After pumping, shut off the valve handle, then
gently shake the nozzle BEFORE removing it from
the container. The spout will open when it senses
pressure greater than one (1) pound per square
inch (psi). Flow restriction will be minimal.
Diaphragm and Check Valve Orientation Detail
Manufacture Date
Information
Ball only in bottom seats
Anti-Drip Nozzle Spout
Nozzle
Outlet Valve with Spring
Upper Holes (2)
Ball Seat - No Cross
Ball (4)
Upper Holes
Cross and Spring
Bottom Holes
10
1-3/4"

Publicité

loading