PRESSURE RELIEF
1.
Apply the trigger lock and put the switch
(1) in the off position.
2.
Turn the pressure control knob (8) to the
lowest setting.
3.
Put the end of the outlet hose (11) in a
suitable container and turn the pressure
relief valve lever (6) to its vertical position
to relieve the pressure.
4.
Press the spray gun firmly against an
earthed metal container and point it
down into the container. Release the
trigger lock and press the trigger to relieve
the pressure in the product.
5.
Apply the trigger lock.
NOTE:
The system is not relieved of pressure
when the pump motor is switched off.
Leave the pressure relief valve lever (6)
in its vertical position until spraying
starts.
USE
FLUSHING OF PRESERVATIVE FLUID
NOTE:
The product must be flushed/tested before
use. The product is tested at the factory with
a fluid that must flushed out of the system
before it is used for the first time.
The preservative lubricant must then be
flushed out from the system before use.
1.
Check that the power switch (1) is
switched off.
2.
Put the end of the outlet hose (11) in a
suitable container and put the end of the
suction hose (10) in an earthed metal
container, partly filled with cleaning fluid,
to flush the fluid from the factory out of the
48
product. Flush out water-based paint with
water and oil-based paint and preservative
with white spirit or the equivalent.
3.
The pressure relief valve lever (6) must be
in its vertical position.
4.
The plug (9) must only be connected to a
correctly earthed power point.
5.
Press the manual valve (4) several times
to release the inlet valve ball.
6.
Turn the pressure control knob (8) to the
lowest setting.
7.
Put the switch (1) in the on position. The
product pump starts and fluid flows in
through the suction hose (10) and out
through the outlet hose (11).
8.
Let the fluid flow out through the outlet
hose (11) for 45 to 60 seconds and then
turn back the pressure relief valve lever (6)
to its horizontal position. Wait until the
pump stops.
9.
Wait about 1 minute and then check that
all the connections are tight. If there is
any leakage, release the pressure and
tighten all the connections and then
repeat steps 1 to 8. Never attempt to stop
leakage with your hands, other parts of
your body, or rags.
10. If there is no leakage put the switch (1) in
the off position, point the spray gun down
in an empty container, release the trigger
lock and press the trigger to empty the
fluid from the system.
11. Apply the trigger lock and turn the
pressure relief valve lever (6) to its
vertical position.
PREPARATION OF MATERIAL
The material to be sprayed must be mixed,
diluted (if applicable) and filtered before use.