EN
4.2.
Pellet mode
Automatic Ignition
The stove can be started with the Start/Stop button in the status display or heat output dis-
play.Optionally, it can be started via IR remote control or via the app.
Pellet ignition is fully automatic and occurs in several phases. These phases are shown on
the display. (Positioning the riddling grate - filling the burner pot - ignition phase 1 - increas-
ing the temperature in the firebox - ignition phase 2 - monitoring ignition - ignition phase 3 -
release or control by the user - full combustion phase).
Pressing the Start/Stop button during the ignition phase terminates ignition. An error mes-
sage "E102" will be displayed if ignition is interrupted.
Pellet mode
In pellet mode, the pellet quantity and combustion air are supplied in accordance with the
heat output setting.
The room temperature required must be specified in the room temperature display. Once
this is attained, the stove automatically regulates to the lowest output level or switches OFF,
if the ECO function is enabled. (See Settings/ECO mode.)
Tapping the 'STOP' button switches the stove to the burn-out or cooling-down phase.
The current room temperature is measured by means of the wired temperature sensor on
the rear side of the unit.
In pellet mode, a fluctuating flue draught or increasing fouling of the flue gas passes is auto-
matically compensated by the flue gas fan. An error message is output only in extreme
cases.
If the door is opened and closed again during pellet mode, the system switches to the oper-
ating phase 'Hybrid start'.
4.3.
Firewood mode
Heat output setting firewood
The heat output setting influences the automatic combustion process. To ensure optimal combustion, the output
should be selected to match the amount of firewood inserted.
Output level 1: Ember maintenance (no firewood combustion)
Output level 2: approx. 1.0 kg of wood
Output level 3: approx. 1.4 kg of wood
Output level 4: approx. 1.7 kg of wood
Output level 5: approx. 2.0 kg of wood
Hybrid start
The hybrid start is used to ignite the firewood via pellet ignition. Here, pellets are injected
and the air dampers for the combustion air supply are opened. This ensures that the fire-
wood placed inside the stove burns optimally.
CAUTION: Make sure that the combustion recess is not completely covered with firewood
(risk of deflagration).
After a few minutes the stove switches to the operating phase 'Firewood start I' to continue
inflaming the firewood.
If the door is opened and closed again during 'Hybrid start'" and then 'NO' is tapped on the
display, the stove switches back to pellet mode.
15
↔
amount of firewood
CLOU DUO, MO DUO
english
www.austroflamm.com
15