If the system voltage DIP Settings Switches are set
to Auto-detect, battery voltage over 15.5V will be
detected as a 24V nominal battery, and the unit will
charge accordingly.
The 12/24V auto selection is done only at start-up,
and the detected system voltage will never change
during operation. It is recommended to set DIPs 2
and 3 to the correct system voltage setting. Only use
the default auto-detect setting if the nominal system
voltage is not known.
Switches 4, 5, 6: Battery Type Selection
Preset EcoPulse battery charging options are shown
in table 3-1 below. All voltage settings listed are
for nominal 12 Volt batteries. Multiply the voltage
settings by two (2) for 24 Volt systems.
NOTE: These settings are general guidelines for use
at the operator's discretion. Consult the battery
manufacturer for optimal battery charge settings.
DIP
Absorp.
Float
Equalize
Switch
Battery
Stage
Stage
Stage
Settings
Type
(volts)
(volts)
(volts)
4-5-6
off-off-off 1 - Sealed*
14.00
13.50
off-off-on 2 - Sealed*
14.15
13.50
14.40
off-on-off 3 - Sealed*
14.30
13.50
14.60
off-on-on 4- AGM/Flooded
14.40
13.50
15.10
on-off-off 5 - Flooded
14.60
13.50
15.30
on-off-on 6 - Flooded
14.70
13.50
15.40
on-on-off 7 - L-16
15.40
13.40
16.00
on-on-on
8 - Custom
Custom
Custom
Custom
* "Sealed" battery type includes gel and AGM batteries
Table 3.1. Battery charging settings for each selectable battery type
10
Installation
Absorp.
Equalize
Equalize
Equalize
Equalize
Equalize
Equalize
Equalize
Time
Time
Timeout
Interval
LVD
LVR
Interval
Interval
(volts)
(volts)
(mins)
(mins)
(mins)
(days)
(days)
(days)
150
11.50
12.60
150
60
120
28
11.30
12.80
150
60
120
28
13.00
11.50
180
120
180
28
11.70
13.20
180
120
180
28
11.90
13.40
180
180
240
28
12.10
13.60
180
180
240
14
12.30
13.80
Custom
Custom
Custom
Custom
Custom
Custom Custom
Custom
Custom
Switch 7: Battery Equalization
Mode
Manual Equalization
Auto Equalization
NOTE: Regardless of DIP 7 setting, manual EQ can be initiated using
the on-board meter command, "Start Equalize". For non-meter
versions, DIP 7 only enables or disables auto equalization - manual EQ
is not available.
Switch 8: Current Switching
Mode
PWM switching
Slow switching
The default (PWM) switching setting (OFF / down) operates
at 300Hz. If load or system noise is an issue, DIP 8 can be set
(ON-up) for slow switching at 1Hz. Standard PWM switching is
recommended when system noise is not a problem.

3.3 Mounting

Inspect the controller for shipping damage. Mount the
EcoPulse to a vertical surface (4-#8 zinc-plated self-
tapping screws are included). Tighten the mounting
screws using care not to crack the plastic case. Do not
install directly over an easily combustible surface since
the heat sink may get hot under certain operating
conditions.
NOTE: The heat sink must be in a vertical
position (fins up and down).
EcoPulse Operator's Manual
Switch 7
OFF
ON
Switch 8
OFF
ON
11