2.2 Installing the keypad

To install and use the keypad (including in timer mode), refer to the instructions supplied with the
keypad.
III

– Default configuration

Restore factory settings by keeping the red button on the electronic board pressed until the clock
turns black.
Location of button on the electronic board:
The full factory configuration is as follows:
• IP configuration by DHCP (DHCP: ON)
• Time zone: EUR
• Synchronisation: Multicast
• Synchronisation address: 239.192.54.1
These four parameters are printed on the electronic board.
• Clock name: "BODET-@MAC"
• Pool period for unicast synchronisation: 15 mins.
• SNMP disabled
• Trap type: V2C
• Temperature alarm threshold: -5°C to +55°C
• Trap status issue period: 24 hr
• No password
• Luminosity: level 3
• 12 hr/24 hr mode: 24 hr
• Eco mode: Nor
• ON & OFF time: 23 hours OFF / 6 hours ON
On the electronic board connector:
Green LED: network activity + power supply
Yellow LED: network type (ON = 100 m, OFF = 10 m)
8
EN