Ethernet Connection
The MobileView terminal is equipped with a 10Base-T interface which supports
TCP/IP protocol at 10MBaud for half-duplex communications.
The Ethernet connector at S3 on the Junction Box provides a connection to an
Ethernet network. The connector uses an 8-pin modular jack connector. Pinouts are
as follows:
Pin #
Ethernet Signal
1
TD+
2
TD-
3
RD+
4
Not Used
5
Not Used
6
RD-
7
Not Used
8
Not Used
Using the PC Card Slot
The PC card slot is a factory installed option and supports Type I, II, and III PC
cards. The following PC cards are available from Allen-Bradley. The terminal does
not support SRAM cards, Cardbus cards, or cards that use 12 volts for programming.
Catalog No.
Description
2711-NM28
8M flash ATA card for storing applications.
2711-NM216
16M flash ATA card for storing applications.
2711-NM232
32M flash ATA card for storing applications.