SP ECI F IC AT I O N S
Installation Requirements
The convection steam oven can be installed in a standard or
flush inset application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum 3 mm reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
If the convection steam oven is installed above or below a
Wolf E series oven in a flush inset application, a 6 mm reveal
is required.
I NSTALLATION R EQUI R EM ENTS
B AS E SU P P ORT
Convection Steam Oven
T R I M O VE R L A P
6 1 0 mm MO D EL 7 6 2 m m M OD E L
Top
5 mm
Bottom
0 mm
Sides
18 mm
Electrical Requirements
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
MI N
45 kg
Locate the electrical supply as shown in the illustrations on
page 4. A separate circuit, servicing only this appliance is
5 mm
required. A ground fault circuit interrupter (GFCI) is not rec-
0 mm
ommended and may cause interruption of operation.
98 mm
Performance may be compromised if the electrical supply is
less than 220 volts.
ELE C T R I C AL R EQ U I R EMEN T S
Electrical Supply
380-415 VAC 2N, 50 Hz
Service
Power Cord
RATING PLATE
Rating plate location
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
220-240 VAC, 50 Hz
3700 W
1.8 m
|
wolfappliance.com