13) Press the button Yes. The display changes e. g.
GB
to:
21 Jun 09:45
O k ?
If date and time are not yet correct, press the but-
ton No and correct the setting from operating step
10). In the other case confirm the setting with the
button Yes. The display returns to:
Do You Want to..
Set Date/Time ?
14) To terminate the time setting, press the button 0
twice so that a signal will sound after exiting
the menu and the display shows date, time, and
<<< UNSET >>> again.
2.3 Switching on and off the function "Chime"
The function "Chime" allows an internal signalizing
even with the alarm control system deactivated. Then
the buzzers in the keypad controllers and the speaker
connected to the alarm control system emit four short
audio signals in case of an alarm recording in a zone
with the feature "Chime". This function can be switched
on and off for all "Chime" zones together via the key-
pad controller.
1) The alarm control system must be deactivated.
Then the display shows:
01 Jan 00:00
<<<
UNSET
2) Enter a valid master access code (user numbers 1
to 3) with the numerical keys (e. g. that of the
default setting 5, 6, 7, 8). The display shows:
Do You Want to..
Set User 1 ?
3) Press the button No within 15 seconds, otherwise
the menu will be exited. The display shows:
Do You Want to..
Test ?
4) Press the button No again. The display shows:
Do You Want to..
Delete Zone ?
5) Press the button No once again. The display
shows:
Do You Want to..
Select Options ?
6) Press the button Yes. The display shows:
Do You Want to..
Program Chime ?
7) Press the button Yes once more. The display
shows:
C h i m e
O f f
14
>>>
(However, if the function "Chime" has already
been activated, the display shows "Chime On"
instead. Then it is possible to switch off this func-
tion with the button No.)
8) Press the button No. The display shows:
C h i m e
O n
9) Confirm with the button Yes. The display returns
to:
Do You Want to..
Program Chime ?
10) To terminate this setting procedure, press the but-
ton 0 twice so that a signal will sound after exiting
the menu and the display shows date, time, and
<<< UNSET >>> again.
3 Activating and Deactivating the Alarm
Control System
Either activate the alarm control system via one of the
keypad controllers (chapters 3.1 to 3.4) or via a key
switch or a code lock, if installed. With a key switch or
a code lock, however, only the full activation mode (all
alarm zones are active) can be switched on.
After the activation the signal for the run of the exit
delay time will sound (for the duration see the overview
on the last page). During this time the monitoring range
must be exited via the zone(s) with an exit delay (fea-
ture "E/E" or "Access").
As an explanation: An "E/E" zone is not activated
after activating the alarm control system before the exit
delay time (exit time) has expired. This feature is espe-
cially provided for doors through which the operators of
the alarm control system enter and leave the building.
The programmed delay time is entered on the last
page.
With an alarm recording in an "access" zone no
alarm will be triggered if another zone with the feature
"E/E" has activated the exit delay before. However, if
this delay has not been activated, a recording imme-
diately triggers an alarm. This feature is especially pro-
vided for motion detectors intended for the access
doors for the operators.
3.1 Full activation mode
In the full activation mode it is possible to trigger an
alarm via all alarm zones (except those with the fea-
ture "ET" and "Alert") in case of a recording.
1) If the function for quick activation is possible
("Quick Set", see overview on the last page), press
the button Quick.
If not, enter a valid access code and actuate
the button Full.
2) The signal for the run of the exit delay time sounds
and the display shows in the meantime:
Exit Now!...
O k !