Code
Error description
The I/O remote control is no
Error 9
longer communicating with
the electronic card
The station has been OFFLINE
Error 10
for >24h
The contactor is working when
it shouldn't be. The Schuko
Error 11
socket-outlet is powered in the
standby condition
78
Solution
Check the Modbus
line connection
Check the power supply to the
I/O remote control
Check the I/O remote control
is working properly
Make sure the component
on the Modbus line is
numbered correctly
Try to restart the station by
disconnecting the power supply
for at least 3 minutes and then
reconnecting it
If the station remains in this
condition, check the connection.
Contact your aftersales service
Check the signal from the
electronic board to the
contactor, to make sure
the former isn't controlling
the latter. If the board isn't
controlling the contactor, make
sure the contactor contacts
aren't jammed.
If necessary, replace the device.