6. Preparation for device installation
When deciding the location of the device and preparing for its installation, a series of instructions linked to its properties must
be followed.
6.1. Environment
•
Position the charging station in a location that can be accessed for installation and maintenance, which permits its use and
the reading of the LED indicators.
•
Do not position any material sensitive to high temperatures in the immediate vicinity of its air outlet.
•
Avoid corrosive environments that could have an influence on the correct operation of the device.
•
It is prohibited to leave any object on the device.
•
In the case of connected devices, avoid positioning them near metal fences or walls which could cause signal disturbance
problems.
6.2. Environmental conditions
The following table shows the device operating conditions in the standard configurations and with the accessories (fan and heater):
Maximum relative humidity without condensation
Remember that it could occasionally produce a small amount of condensation as a result of temperature changes. Despite their built-in
protection therefore, the charging stations must be monitored when used in areas where all the previously indicated conditions are
unlikely to be satisfied.
Never connect the device to the voltage supply when there is condensation.
NB: if the ambient temperature is higher than 40°C, a cover must be installed to protect the device from direct sunlight.
6.3. Support and fixing surface (column version)
Ensure there is a firm, even surface for anchoring the device, which must be perfectly vertical.
The installation surface must be suitably prepared according to the type of ground, to guarantee that the device is stable during use.
You are therefore advised to use the base supplied (column version), fixing it to the ground by means of tie-rods (not supplied) or plugs,
or embedded in cement.
56
Environmental conditions
Minimum operating temperature
Maximum operating temperature
Preparation for device installation
Column
WallBox
-25°C
-25°C
50°C
50°C
95%
95%
7.55.4.515.2 - Installation and Operation Manual