Dimplex DHW 300 Instructions De Montage Et D'utilisation page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Menu block
Menu item
Solar
Selection
Switch-on difference
Switch-off difference
Max. cylinder temp.
Max. collector temp.
(only visible for devices with additional heat exchanger and OFF or Bivalent selected)
2nd heat genera-
tor
Selection
Bivalence temperature
Photovoltaic
Electric heater
Set temperature
Information
Operating status
Runtimes
Soft. vers.
Hardware
Serial number
Service
Enter password
EN-10
Parameter
Value
Bivalent
6 K ... 8 K ... 10 K
2 K ... 4 K ... 6 K
60 °C ... 65 °C ... 85 °C
125 °C ... 130 °C ... 135 °C
Bivalent
-8 °C ... 10 °C ... 15 °C
35 °C ... 45 °C ... 60 °C
Cylinder top
Cylinder bottom
Air inlet
Collector temp.
Current setpoint
Defrost sensor
Fan
Compressor
Electric heater
Power
Operating mode
Unit
Fan
Compressor
Electric heater
451905.66.01a · FD 0102
Choice of additional heat source
Off
Off: (no add. heat source)
Bivalent: 2nd heat generator, e.g. oil, gas or wood boiler
Sol
Sol: Thermal solar energy system
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched on
Sets the temperature difference between the collector and cylinder
temperature at which the solar pump should be switched off
Sets the maximum cylinder temperature that is permissible when
solar gain is available
Sets the maximum permissible temperature on the collector
Choice of additional heat source
Off
Off: (no add. heat source)
Bivalent: 2nd heat generator, e.g. oil, gas or wood boiler
Sol
Sol: Thermal solar energy system
Limit temperature for the 2nd heat generator. The heat pump is
blocked below this temperature
Yes
Activates the electric heater (parallel to the heat pump) in photovol-
taic mode
No
Entry of the domestic hot water setpoint, which is active when pho-
tovoltaic inlet is connected. The increased setpoint is also active if
the air intake temperature does not allow the heat pump to operate.
In this case, the request is processed with the electric heating ele-
ment or, where present, the 2nd heat generator.
Display of the cylinder temperature top (R3)
Display of the cylinder temperature bottom (R5)
Display of the air temperature (R1)
Display of the collector temperature (R13 only on models with addi-
tional heat exchanger and Sol selected as 2nd heat generator)
Displays the current domestic hot water setpoint
Display the defrost (only on models with defrost)
Shows the switching status of the fan
Shows the switching status of the compressor
Shows the switching status of the electric heater
Shows the calculated power consumption of the device
Displays the current operating mode
Displays the operating hours
Shows the runtime of the fan
Shows the runtime of the compressor
Shows the runtime of the electric heater
Shows the software version
Shows the hardware version
Shows the serial number
Password-protected area for after-sales service
DHW 300 - DHW 300+
Description
www.glendimpex.de