Storage and transport
3.1 General
The domestic hot water heat pump should always be stored
and transported packaged in an upright position, without being
filled with water. If handled carefully, the device can be trans-
ported over short distances with a maximum tilt angle of 45°.
Ambient temperatures between -20 and +60 °C are permissible
during transport and storage.
3.2 Fork lift (or lift truck) transport
The domestic hot water heat pump must remain mounted on
the pallet when being transported with a fork lift. The pump
should be lifted slowly. Because of its high centre of mass, the
domestic hot water heat pump must be secured against top-
pling. To prevent damage, the domestic hot water heat pump
must be lowered onto a level surface.
3.3 Manual transport (factory
default)
The wooden pallet can be used underneath the device for the
purpose of manual transportation. A second or third carrying
position can be created with the help of ropes or carrying slings
(these may be wrapped around the cylinder casing and at-
tached to the water pipe nipples). When transporting the heat
pump in this manner (or with a hand truck), do not, under any
circumstances, exceed the max. tilt angle of 45° (see illustra-
tion).
45°
CAUTION!
The device cover cannot be used for carrying (the cover
cannot withstand significant forces).
www.glendimpex.de
3.4 Transport in carrier (accessory
The carrying bag accessory can be used to transport the heat
pump horizontally within the building. For this, the cover must
be removed and the guard plate supplied with the carrying bag
must be mounted. The guard plate is fixed in place between the
transport lug of the compressor and the dividing wall using the
mounting material provided.
Fix the guard plate
on the compressor
CAUTION!
Once the heat pump has been set up, the guard plate must be
removed!
It is important to ensure that the device is not transported over-
head during the entire transport process.
CAUTION!
The heat pump must not be transported overhead.
451905.66.01a · FD 0102
with locking plate)
guard plate
Contact surface
heat pump in
the carrying bag
English
Fix the guard plate
on the dividing wall
EN-5