IN S TA L L AT I O N
Anti-Tip Bracket
To prevent the range from tipping forward, the anti-tip
bracket must be installed. To ensure the anti-tip bolt
engages the bracket, refer to the chart and illustration below
to determine proper placement.
AN T I-T IP B RA C K E T
30" Range
36" Range
48" Range
60" Range
I NS TAL L B RA C K E T
Drywall application: After properly positioning the anti-tip
bracket, mark the holes, then use a Phillips screwdriver or a
low rpm power drill to drive the wall anchor into the surface
of the wallboard until flush. Pre-drill the holes if needed. For
hard wallboard or double-board construction, use a
7
bit. For solid plaster, use a
tion below. Use the #8 screws and flat washers to fasten the
bracket to the wall.
Wood floor application: After properly positioning the anti-
tip bracket, drill
3
/
"
pilot holes through the floor. Use the
(5)
16
#12 screws and flat washers to secure the bracket to the
floor.
Concrete floor application: After properly positioning
3
the anti-tip bracket, drill
/
"
8
minimum of 1
1
/
"
deep. Use the
(38)
2
secure the bracket to the floor.
ANTI-TIP
BRACKET
A
Anti-tip bracket location
3
/
16
9
/
16
3
/
16
5
/
16
1
/
" drill
4
/
" drill bit. Refer to the illustra-
16
holes into the concrete a
(10)
3
/
" wedge anchors to
8
WALL
ANCHOR
ANTI-TIP
BRACKET
Wall anchor installation
AN TI- TIP B OLT AD J U STM EN T
Once the bracket is secure, adjust the anti-tip bolt so the
top of the washer is
the range into the opening and verify the anti-tip bolt is
engaged. Refer to the illustrations below.
A
"
(5)
"
(14)
"
(5)
"
(8)
ANTI-TIP
BOLT
7
/
"
8
(22) MAX
Anti-tip bolt adjustment
7
/
"
maximum from the floor. Slide
(22)
8
Anti-tip bolt engaged
wolfappliance.com
ANTI-TIP
DEVICE
ENGAGED
|
9