SPE C IF I CAT I ON S
Gas Supply
Installation must comply with local codes or, in the absence
of local codes, with the National Fuel Gas Code.
Locate the gas supply within the shaded area shown in the
illustration on the following page.
The range is equipped for use with natural or liquid propane
(LP) gas. It is design certified by the Canadian Standards
Association (CSA) for natural or LP gases. The product
rating plate has information on the type of gas that should
be used. For rating plate location, refer to the illustration
below. If this information does not agree with the type of gas
available, check with the local gas supplier. The gas pres-
sure regulator is built into the unit.
GA S REQ U IR EM EN T S
NAT U R A L G AS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
L P G AS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
RATING PLATE
Rating plate location
WC
5"
(12.5 mb)
7"
(17.5 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
WC
10"
(25 mb)
11"
(27.4 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
The range must be connected to a regulated gas supply.
The supply line must be equipped with an approved external
gas shut-off valve located near the range in an accessible
location. Do not block access to the shut-off valve. Refer to
the illustration below.
A gas supply of
3
/
"
ID line must be provided to the
(19)
4
range. If local codes permit, a certified, 3'
or
3
/
"
ID flexible metal appliance connector is recom-
(19)
4
mended to connect the units
gas supply line. Pipe joint compounds suitable for use with
natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of .5 psi
. The appliance must be isolated from the gas
(3.5 kPa)
supply piping system by closing its individual manual shut-
off valve during any pressure testing of the system at test
pressures equal to or less than .5 psi
Wolf natural gas ranges will function up to 10,250'
in altitude without adjustment and LP gas ranges will func-
tion up to 8,600'
. If the installation exceeds these
(2621 m)
elevations, contact an authorized Wolf dealer for a high
altitude conversion kit.
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve
long,
1
/
"
(.9 m)
2
1
/
" NPT female inlet to the
2
.
(3.5 kPa)
(3124 m)
|
wolfappliance.com
(13)
5