DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES

These vent hoods must be installed 30" min. to 36" max.
above the standard 36" high cooking surface. When
installed with the warming shelf, allow 32" min. to 38"
max. clearance. The exact hood installation height is
determined by the ceiling height.
1. M easure the exact ceiling height.
2. Review the chart at right to determine the range
of possible hood installation heights that can be
accomplished with one or more duct covers.
3. Increase or decrease hood installation height to
accommodate the fixed 6" or 12" duct covers.
4. D uct covers may be stacked, in various combinations,
to reach ceiling heights.
Straight or Taper-Sided Hoods
Duct Covers
Ceiling Height
to Floor
NOTE: Minimum ceiling height for REAR WALL
EXHAUST with duct covers is 8'4" when installing at 30"
above countertop using 10" elbow
1" = 2.5 cm; 1' = 0.3 m
49-80152 Rev. 8

Advance Planning

18" Hood
Height
Installation Height
*Possible
Hood
Actual Ceiling
Installation
Height
Height
7' 11"
35"
8' 0"
30"
8' 0"
36"
8' 1"
31"
8' 2"
32"
8' 4"
33"
8' 4"
34"
8' 5"
35"
8' 6"
30"
8' 6"
36"
8' 7"
31"
8' 8"
32"
8' 9"
33"
8' 10"
34"
8' 11"
35"
9' 0"
30"
9' 0"
36"
9' 1"
31"
9' 2"
32"
9' 3"
33"
9' 4"
34"
9' 5"
35"
9' 6"
30"
9' 6"
36"
9' 7"
31"
9' 8"
32"
9' 9"
33"
9' 10"
34"
9' 11"
35"
10' 0"
30"
10' 0"
36"
10' 1"
31"
10' 2"
32"
10' 3"
33"
10' 4"
34"
*Based on 36" countertop height.
NOTE: Additional duct covers may be used to reach higher ceilings.
6" Duct
12" Duct
Covers
Covers
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
2
2
2
2
2
2
1
1
1
2
1
2
1
2
1
2
1
2
3
2
1
3
3
3
3
5

Publicité

Chapitres

Table des Matières
loading

Table des Matières