Installation
12. Finish surrounding wall. There
are 3 different options for fin-
ishing the wall:
CAUTION: Do not remove the
trim around the opening of the
unit (Figure 3).
• Permanent - install drywall
right up to the flange that sur-
rounds the opening (Figure 4).
!
NOTE: An air inlet that is a
minimum of 14 in
required for optimum mist produc-
tion, for minimum dimensions
(Figure 4).
• Semi Permanent - finish
around edge using flashing
material (not included).
• Flexible - create opening big
enough to access mounting
flanges and a false front that
can be removed.
Figure 4
(88 cm
is
2
2)
>14 in
2
2
2
>88cm
>88cm
(>88 cm
2
)
?
?
>14 in
(>88 cm
>14 in
2
2
(>88 cm
)
Bathroom Installation
This firebox must be protected
by a GFI circuit. If a receptacle
is used it must be readily acces-
sible.
To prevent electrical shock this
unit is an electrical appliance
that is not watertight and must be
installed as to prevent water from
entering the unit. This unit must
be installed away from showers,
tubs, etc. Never locate fireplace
where it may fall into a bathtub or
other water containers. Keep tow-
els and other combustible materi-
als 3 feet (0.9 m) away from the
front of the unit.