WARNING! Risk of infection
The condensate may be contaminated with
pathogens.
Ü Never drink the condensate.
Ü Regularly pump off the condensate.
Avoid leaving condensate in the collect-
ing vessel or in the condensate drain
hose for a longer period of time.
Operating conditions
The device is intended for mobile or station-
ary use indoors, on construction sites, as
well as in garages and storage rooms. The
device operates efficiently:
At temperatures between +5 °C and
+32 °C and within a relative air humidity
range of 40 % to 100 %.
Ideal room temperature range: 20 °C to
27 °C.
In enclosed rooms where there is as
little air exchange as possible.
Placed at close as possible to the
centre of the room.
When the dry air discharged by the
device is directed towards the humid
part of the room.
Do not use the device under the following
ambient conditions:
Rooms with a potentially explosive at-
mosphere, or an atmosphere containing
sulphur or salt.
Atmospheres with high solvent or dust
concentration.

7 Transport and installation

Transport
WARNING! Risk of injury from device
toppling over
Ü Transport the device in an upright posi-
tion and secure it against tipping or slip-
ping.
Ü Place the device on a level, firm surface.
WARNING! Risk of injury during machine
transport
Ü To transport the device, use the handle
and the castors.
Ü For heavy loads, work in teams of two
and use suitable lifting gear.
Procedure
1. Before transporting the device, empty
the condensate tank.
2. Ensure that the drain hose is removed
from the device and that the mains plug
is disconnected.
3. Transport the device to the location of
operation.
4. To transport heavy loads, work in teams
of two and use suitable lifting gear.
5. When the device is at its location of op-
eration, apply the castor brake.
NOTICE! Ensure that the air can circulate
freely around and through the device. Do
not cover the air inlet and outlet open-
ings. The distance between the air outlet
and the air filter must be minimum 1 m.
Unpacking
1. Remove the device from the cardboard
box and place it on the ground.
2. Check the scope of delivery for com-
pleteness.